Nanobubble case studies from India
Four pilots, with the data tables and the limits of each: the scale, what else was used and what was not measured.

How we work
Every figure on this site comes from the pilot report for that project. We state the scale, any co-treatments and what was not measured. Percentage changes are calculated from the tables. Results depend on the site, and we agree targets with you after a water assessment.

Pirana sewage treatment plant, Ahmedabad (180 MLD)
COD from 145.88 to 20.84 mg/L with oxygen; E. coli below 2 MPN/100 mL with ozone. One sample, 60-minute batches.
Read the case study
Wankhede Stadium, Mumbai
Ammonia from 1.5 to below 0.5 mg/L, TDS from 750 to 550 mg/L over 30 days.
Read the case study
Tengra tank trial, Hajo, Assam
Day-100 survival 88% in the control against 95% and 92% in nanobubble tanks. Operating conditions differed.
Read the case study
Open-pond carp pilot, Nadipar, Assam
Dissolved oxygen 3.5 to 7.6 mg/L and pond biomass about 3.5 times over 100 days. No control pond.
Read the case studyTell us about your water body or plant
We agree targets after a water assessment, then run a pilot before any scale-up.