Avior Aqua

Rao Talao, Mira Bhayandar: nanobubble treatment of a 6,000 m³ urban pond

Rao Talao is a 6,000 m³ urban pond in Mira Bhayandar, maintained by the Mira Bhayandar Municipal Corporation (MBMC). Avior Aqua is treating the pond in place with nanobubble generators mounted on floating frames. An NABL-accredited laboratory tested the water before treatment in June 2026 and again in November 2026.

Drone view of Rao Talao, Mira Bhayandar, after nanobubble treatment, with clear water and the floating nanobubble unit at the centre
After
Turbidity (NTU)
94 → 1.0
Total suspended solids (mg/L)
342 → 4
BOD (mg/L)
58 → 10
COD (mg/L)
102.4 → 21.6

Before: 3 June 2026. After: 2 November 2026. As stated in the laboratory reports.

Summary

Rao Talao is a 6,000 m³ urban pond in Mira Bhayandar, treated in place with nanobubble generators for MBMC. An NABL-accredited laboratory sampled it on 3 June 2026 and 2 November 2026. Between the two samples, turbidity went from 94 to 1.0 NTU and TSS from 342 to 4 mg/L.

Client
Mira Bhayandar Municipal Corporation (MBMC)
Site
Rao Talao, Mira Bhayandar, Maharashtra
Water body
Urban pond, about 6,000 m³
Treatment
In-place nanobubble treatment; generators on floating stainless-steel frames with pontoons and mesh intake cages
Status
Ongoing (results as of November 2026)
Testing
Varni Analytical LLP, NABL-accredited (ISO/IEC 17025:2017)

The pond

Rao Talao sits in a dense residential area, ringed by a walkway, play areas and palms. Before treatment the water was green and turbid, with high suspended solids.

What Avior installed

Nanobubble generators were placed in the pond on floating stainless-steel frames, with mesh cages on the water intakes. The units treat the water where it is, with no draining, dredging or pumping to a plant.

Results

Samples were collected on 3 June 2026 (before) and 2 November 2026 (after) and tested by Varni Analytical LLP. The figures below are as stated in the laboratory reports.

Rao Talao water test results, before and after treatment
ParameterUnitMethodBefore (3 Jun 2026)After (2 Nov 2026)
TurbidityNTUIS 3025 (Part 10) : 202394.001.0
Chemical oxygen demand (COD)mg/LIS 3025 (Part 58) : 2023102.4021.60
Biochemical oxygen demand (BOD)mg/LIS 3025 (Part 44) : 202358.0010.00
Total suspended solids (TSS)mg/LIS 3025 (Part 17) : 2022342.004.00
Ammoniamg/LIS 3025 (Part 34) : 19880.14Not detected (below 0.02)
E. coliMPN/100 mLIS 1622 : 19811,600More than 1,600
Total faecal coliformMPN/100 mLIS 1622 : 19811,600More than 1,600

Questions about Rao Talao

Where is Rao Talao?

In Mira Bhayandar, Maharashtra. It is a 6,000 m³ urban pond maintained by MBMC.

How was the water treated?

With Avior Aqua nanobubble generators on floating frames, treating the water in place.

Who tested the water?

Varni Analytical LLP, an NABL-accredited laboratory, on samples collected on 3 June 2026 and 2 November 2026.

Tell us about your site

We reply within one working day.

Planning work on a pond or lake?

Send us its size and a recent water test, and we reply within one working day.

Contact